Dynamic Filter press HPHT
Product Details:
| Place of Origin | Zhejiang, China (Mainland) |
|---|---|
| Brand Name | RIGCHINA |
| Model Number | DHFP-1 |
Payment & Shipping Terms:
| Packaging Details: | Dimensions 12.5 x 17.75 x 28 in (305 x 455 x 711 mm) Weight 170 pounds (77 kg) |
|---|---|
| Delivery Time: | 15 days |
| Payment Terms: | L/C,T/T,Western Union,MoneyGram |
| Supply Ability: | 200 Set/Sets per Month |
Detailed Product Description
Dynamic HPHT filtration testing determines if fluid is properly conditioned to drill through permeable formations. Test results include two numbers: the dynamic filtration rate and the cake deposition index (CDI). The dynamic filtration rate is calculated from the slope of the curve of volume versus time. The CDI is calculated from the slope of the curve of volume/time versus time.
Utilizing a wide range of available filter mediums, the DYNAMIC HPHT filtration system can be heated and pressurized to provide the closest possible simulation of down-hole conditions. Several safety features have been designed into the system to protect the user and help ensure reliable test results.
The filter medium is a thick-walled cylinder with rock-like characteristics to simulate the build-up of filter cake on the formation. The filter medium is available in varying porosities and permeabilities to simulate down hole formations.
Filtration occurs radially from the inside of the filter core to the outside. At the same time, the filter cake is formed on the inside of the filter core to simulate filter cake formation on the wall of a borehole. Following completion of a test, the filter cake can be inspected visually. A polished stainless steel shear bob runs through the central axis of the filter core. The shear bob is rotated to produce a concentric cylinder-type shear across the filtration surface.
The LCD display allows monitoring of real-time test results, which are printed for further analysis and filing of test results. The DYNAMIC HPHT filtration system also features an interface port, which allows downloading of ASCII-formatted data to a personal computer. The system is fully automatic with a built-in computer controller.
Through menu-driven software, the user can establish up to 20 sequence steps to program the following testing parameters:
- Temperature
- Pressure
- Differential pressure
- Shear rate
Operational Features
Fully automatic control with built-in computer controller; 8-line, 40-column LCD display; 16-key input control; menu-driven software
Ramping of temperature, pressure, differential pressure, and shear rate can be established with up to 20 sequence steps
Automatic volume collection of filtrate; data reported in 1/3 cc increments
Interface port for downloading of ASCII-formatted data to a personal computer via RS232 link and operators communication program
Each data point comprised of elapsed time, total volume of filtrate, pressure, differential pressure, sample temperature, and shear rate
Data from most recent test stored in non-volatile memory, which allows user to view data on LCD display, print for hardcopy analysis, or download to PC
Two test sequences stored in memory:
- Standard test that cannot be edited by operator
- Most recent test sequence used, which can be retrieved and edited before use
Audible tones to alert user of outer limit parameters
Built-in pump for automatic purge cycle to saturate the core and clear air from pressure lines; magnetically-driven pump to eliminate dynamic seals and leakage potential
Single pressure port for high pressure; back pressure regulated automatically
External yoke cell that requires no threaded closures; threaded bottom cap to facilitate cell loading and unloading
Magnetically-driven shear bob with rpm monitoring; 30-1000 rpm rotation speed
Quick-connect fittings on filtrate hoses
Safety Features
Rupture disk on high pressure gas supply
Safety pressure relief valve on the heated, pressurized cell
Independent over-temperature shutdown
Heater and motor cut-off interlock door when door is opened
Automatic cool-down upon completion of test
Proper positioning of cell and collector required before system will pressurize
Pressure must be relieved to less than 5 psig before the cell can be disassembled for cleanup
Cell design uses no stressed threaded closures, no set screws or caps which require tightening
Cell constructed of Monel K500 with stainless steel end caps
Unit has no welded joints on stressed parts
All stainless steel pressure fittings
Ordering Information
Specifications
Working pressure | 2500 psig |
Maximum temperature | 500°F |
Maximum differential pressure | 500+ psig |
Maximum power requirements | 1500 watts |
Heater power | 1200 watts |
Power supply | 120/240V, 50/60 Hz |
Sample volume | 250 cc |
Filtrate volume | 50 cc |
Shear bob drive | ¼ hp motor with belted magnetic drive; |
Shear rate constant | 2693 1/s per rpm (no filter cake) |
Initial shear rate range (with standard bob) | 9, to 269 1/s |
Dimensions | 12.5 x 17.75 x 28 in (305 x 455 x 711 mm) |
Weight | 170 pounds (77 kg) |
Dynamic Filter press HPHT
Other Products from this Supplier
See more
Filter Press, High Pressure-High Temperature Filter Press, Bench Mount Filter Press products from this supplier.
Product Showcase[10]
Products
- DRILLING INSTRUMENTATION [27]
- MUD TESTING EQUIPMENTS [114]
- TORQUE INDICATORS,ROTARY [1]
- Traction Type Dynamometer [1]
- PRESSURE GAUGE [49]
- CNG Level Indicators [3]
Company Info
Rigchina Group Company
[China (Mainland)]
[Verified Member]
City: Jinhua
Province/State: Zhejiang
Country/Region : China (Mainland)
Business Type:Manufacturer
Online Postings: Products